COMPARISON OF NON-UNIFORMITY-CORRECTION ALGORITHMS USING 
MULTIPLE REPEAT T1-WEIGHTED MRI SCANS OF A SINGLE SUBJECT

Six T1-weighted brain volumes of a normal volunteer were acquired over a six-month period on a Siemens Vision 1.5T MRI scanner using the 3DFLASH protocol (TR 35 msec, TE 6 msec, flip angle 45 degrees, one excitation, 165 x 220 mm FOV, 192 x 256 matrix, 100 slices, voxel dimensions 0.86 x 0.86 x 2.0 mm). Stripping (cortical isolation) masks were created for each volume as described above, and the raw volumes and their corresponding masks were aligned to a common coordinate system using the AIR 3.0 algorithm; to insure that data interpolation effects were similar for the six test volumes, for each volume an average transform to a Talairach reference volume was employed. After the non-uniformity-correction algorithms were run on the six aligned brain volumes, each corrected data volume was mean-normalized to the corresponding input volume to facilitate quantitative comparisons between algorithms.

    - Biased Brain Phantom Data (Figs. 1-4)
    - High-Resolution T1-weighted MRI Scans from Two Different Centers (Figs. 11-12)

    - Return to Introduction Page


Figure 5     Figure 6     Figure 7     Figure 8      Figure 9     Figure 10

Figure 7
Voxel-wise scatter plots of an uncorrected MRI volume (x-axis) vs. each of six non-uniformity -corrected volumes (y-axis). The n3-, bfc-, eq-, hum- and cma-corrected volumes are more highly correlated with the original (non-uniform) volume than is the spm-corrected volume.
 

 


© 2000 by the International Neuroimaging Consortium with funding from the 
Human Brain Project and by the Regents of the University of Minnesota. 
Contact: webmaster@pet.med.va.gov
The University of Minnesota is an equal opportunity educator and employer.